Solar Panel Tilt Calculator

This solar panel tilt calculator finds the best angle for solar panels from your latitude. Enter the latitude and the solar panel tilt calculator returns the best fixed year-round tilt, the summer, spring and autumn, and winter angles for adjustable racks, the direction to face, the noon sun height through the year, and the row spacing that keeps rows on a flat roof or field from shading each other.

°
m
°

Results

Enter your values and press Calculate to see results.

The Solar Panel Tilt Calculator is part of our Solar collection. Browse more solar to size, convert, and check your work alongside this tool.

What the solar panel tilt calculator does

Solar panels produce the most when sunlight hits them straight on. The sun rides higher in summer and lower in winter, and its average height depends on how far you are from the equator, so the best fixed angle depends mainly on latitude. The solar panel tilt calculator uses a fit to global solar data for the year-round optimum, gives seasonal angles for adjustable mounts, and works out the spacing between rows from the lowest noon sun of the year.

Year-round tilt = 1.3793 + φ × (1.2011 + φ × (−0.014404 + φ × 0.000080509))

Solar tilt angle by latitude

The year-round formula comes from a 2018 study by Jacobson and Jadhav that modeled panels at thousands of locations, including clouds; it returns angles a little flatter than the old rule of tilt equals latitude, because diffuse light and the long summer days favor a flatter panel. Seasonal angles follow the classic rule:

Summer = latitude − 15°, spring and autumn = latitude, winter = latitude + 15°
Noon sun height = 90° − latitude ± 23.44°

For row spacing, a panel of length L at tilt β stands L × sin β high and casts a shadow of that height divided by the tangent of the winter noon sun height. The row pitch is the shadow plus the panel footprint L × cos β.

Solar panel tilt calculator example

A home at latitude 51° N, such as London or Cologne:

Year-round tilt = 35.9°, facing true south
Winter noon sun = 90 − 51 − 23.44 = 15.6°

A 1.7 m panel at 35.9° stands 1.0 m high and casts a 3.58 m shadow at winter noon, so rows need a pitch of 4.95 m front to front. Adjustable racks would sit at 36° in summer, 51° in spring and autumn, and 66° in winter.

How to use the solar panel angle calculator

Enter your latitude in degrees; you can read it from any map app. Use a negative number south of the equator. For row spacing on a flat roof or ground mount, enter the length of the panel up the slope, about 1.7 m for a portrait 400 W module, and leave the tilt at 0 to use the year-round optimum, or enter the tilt your rack uses. Press Calculate.

Reading the optimal solar panel angle

Output changes slowly near the optimum: a tilt 10° off costs only about 1 to 3% of the annual yield, so a roof pitch close to the result needs no tilting frame. Steeper panels shed snow and favor winter output; flatter panels catch more in summer and suit east-west layouts that spread production across the day. The row spacing is set for the noon sun on the shortest day; for a shade-free window from 10:00 to 14:00, add about 20 to 40%.

When to use a solar tilt angle by latitude tool

  • Setting the frame angle for a flat roof or ground mount
  • Checking whether a roof pitch suits solar panels
  • Planning seasonal adjustments for off-grid systems
  • Spacing rows so they do not shade each other
  • Comparing sites at different latitudes

Common solar panel tilt calculator mistakes

  • Using magnetic south. Face true south; correct for declination.
  • Spacing rows for summer sun. Use the low winter sun.
  • Tilting too flat in snowy areas. Below about 15° snow stays on.
  • Forgetting the sign of latitude. South of the equator, face north.

Tips for the best tilt for solar panels

  • Use the roof pitch if it is within 10° of the optimum.
  • Keep at least 10° tilt so rain cleans the panels.
  • Check local shading from trees and chimneys too.

Solar panel angle on a pitched roof

On a pitched roof the panels usually lie flat on the tiles, so the roof pitch is the tilt. A typical 30 to 45° roof is close to the optimum across most of Europe and North America, and adding tilt frames on a pitched roof rarely pays. Convert a roof slope given as rise over run to degrees with the roof pitch calculator: a 7/12 roof is 30.3°, close to ideal at latitude 40°. East and west facing roofs lose about 15 to 20% compared with south, which you can offset with an extra panel or two sized with the solar panel calculator.

Solar panel row spacing on flat roofs

On flat roofs, steep tilts need wide rows, so installers often use 10 to 15° racks in an east-west layout that fits far more panels into the same area. The yield per panel drops a little, but the yield per square meter of roof rises. Whether that trade pays depends on the module price and your electricity price, which the solar payback calculator compares in years.

Best angle for solar panels by latitude

LatitudeYear-round tiltSummer tiltWinter tiltWinter noon sunRow pitch, 1.7 m panel
25°23.7°10°40°41.6°2.33 m
30°26.6°15°45°36.6°2.55 m
35°29.2°20°50°31.6°2.83 m
40°31.5°25°55°26.6°3.23 m
45°33.6°30°60°21.6°3.8 m
48°34.7°33°63°18.6°4.28 m
51°35.9°36°66°15.6°4.95 m
54°36.9°39°69°12.6°5.94 m
57°38°42°72°9.6°7.55 m
60°39°45°75°6.6°10.62 m

Solar panel angle for common cities

CityLatitudeYear-round tilt
Miami25.8°24.2°
Los Angeles34.1°28.8°
New York40.7°31.8°
Toronto43.7°33.1°
Munich48.1°34.8°
Berlin52.5°36.4°
London51.5°36°
Hamburg53.6°36.8°
Sydney-33.9°28.7°

Solar Panel Tilt Calculator FAQ

What is the best angle for solar panels?

For a fixed panel, a little less than your latitude: about 30° at latitude 40° and 36° at latitude 51°, facing true south in the northern hemisphere.

Should solar panels be tilted at latitude?

Latitude is a good angle for spring and autumn. For the whole year a slightly flatter tilt gives a little more energy at most sites.

How much does a wrong tilt cost?

Little near the optimum: 10° off usually costs 1 to 3% of the yearly output. A flat panel at 51° latitude loses about 10 to 15%.

How far apart should solar panel rows be?

Far enough that the winter noon shadow clears the next row. At 51° latitude, a 1.7 m panel at 36° needs about 5 m between row fronts.